An Analysis of Potential Predictors of Tunneled Haemodialysis Catheter Infection or Dysfunction

Authors

  • Raja Jibran Akbar Department of Nephrology, Pak-Emirates Military Hospital, Rawalpindi/National University of Medical Sciences (NUMS) Pakistan
  • Sohail Sabir Department of Nephrology, Pak-Emirates Military Hospital, Rawalpindi/National University of Medical Sciences (NUMS) Pakistan
  • Khalid Mehmood Raja Department of Nephrology, Pak-Emirates Military Hospital, Rawalpindi/National University of Medical Sciences (NUMS) Pakistan
  • Sajid Ali Shah Department of Peads, Combined Military Hospital, Mardan/National University of Medical Sciences (NUMS) Pakistan
  • Umair Ijaz Malik Department of Nephrology, Pak-Emirates Military Hospital, Rawalpindi/National University of Medical Sciences (NUMS) Pakistan
  • Wajiha Department of Nephrology, Pak-Emirates Military Hospital, Rawalpindi/National University of Medical Sciences (NUMS) Pakistan

DOI:

https://doi.org/10.51253/pafmj.v76i7.11511

Keywords:

Chronic Kidney Disease, Infection, Thrombosis, Tunneled Double Lumen Catheter

Abstract

Objective: To assess various factors contributing to infection and dysfunction of tunneled double lumen catheter in patients with End Stage Renal Disease.

Study Design: Cross-sectional study.

Place and Duration of Study: Nephrology Department, Pak-Emirates Military Hospital (PEMH) Rawalpindi, Pakistan from Jan 2022 to Jan 2023.  

Methodology: All patients with chronic kidney disease having tunneled double lumen (TDL) catheter for hemodialysis were included in the study. Line infection was defined by either clinical picture of infection or by culture and sensitivity or both. Reasons for dysfunction included bleeding (BL) and thrombosis / clotting (TH) of the catheter. TDL was considered successful if it remained in situ without infection (IN) or dysfunction till establishment of fistula.

Results: Most of the patients were male compared to female i.e. 129(64.5%) vs 71(35.5%). Right internal jugular vein (IJV) was used for insertion in 174(87%) whereas left IJV was used in 26(13%) patients. The line was infected in 14(7%) patients, thrombosis of the line occurred in 6(3%) patients while bleeding was observed in 3(1.5%) patients. Absolute neutrophils count, platelets count and site of insertion were significantly related with infection and dysfunction of TDL catheter.

Conclusion: In most patients, TDL catheter was successful. Reason for failure included infections, thrombosis and bleeding. Absolute neutrophils count, platelets count and site of insertion were significantly related with infection and dysfunction of tunnel catheter.

Downloads

Download data is not yet available.

References

1. Inker LA, Astor BC, Fox CH, Isakova T, Lash JP, Peralta CA, et al. KDOQI US commentary on the 2012 KDIGO clinical practice guideline for the evaluation and management of CKD. Am J Kidney Dis 2014; 63(5): 713-735.https://doi.org/10.1053/j.ajkd.2014.01.416

2. Chen W, Zhou ZQ, Ren YQ, Zhang L, Sun LN, Man YL, et al. Effects of long non-coding RNA LINC00667 on renal tubular epithelial cell proliferation, apoptosis and renal fibrosis via the miR-19b-3p/LINC00667/CTGF signaling pathway in chronic renal failure. Cell Signal 2019; 54(1): 102–114.

https://doi.org/10.1016/j.cellsig.2018.10.016

3. Dai P, Chang W, Xin Z, Cheng H, Ouyang W, Luo A. Retrospective Study on the Influencing Factors and Prediction of Hospitalization Expenses for Chronic Renal Failure in China Based on Random Forest and LASSO Regression. Front Public Health 2021; 9: 678276.

https://doi.org/10.3389/fpubh.2021.678276

4. Ammirati AL. Chronic kidney disease. Rev Assoc Med Bras 2020; 66(suppl 1): s03–09.

https://doi.org/10.1590/1806-9282.66.S1.3

5. Centers for Disease Control and Prevention, US Department of Health and Human Services. Chronic kidney disease in the United States. Atlanta, GA: US department of health and human services, centers for disease control and prevention 2021 [Internet]. (cited March 25 2024). Available from:

https://www.cdc.gov/kidney-disease/php/data research/index.html

6. Dias DB, Mendes ML, Caramori JT, Falbo dos RP, Ponce D. Urgent-start dialysis: comparison of complications and outcomes between peritoneal dialysis and haemodialysis. Perit Dia Int 2021; 41(2): 244-252.

https://doi.org/10.1177/0896860820915021

7. van Oevelen M, Abrahams AC, Weijmer MC, Nagtegaal T, Dekker FW, Rotmans JI, et al. Precurved non-tunnelled catheters for haemodialysis are comparable in terms of infections and malfunction as compared to tunnelled catheters: A retrospective cohort study. J Vasc Access 2019; 20(3): 307-312.

https://doi.org/10.1177/1129729818805954

8. Sohail MA, Vachharajani TJ, Anvari E. Central venous catheters for hemodialysis—the myth and the evidence. Kidney Int Rep 2021; 6(12): 2958-2968.

https://doi.org/10.1016/j.ekir.2021.09.009

9. Poinen K, Quinn RR, Clarke A, Ravani P, Hiremath S, Miller LM, et al. Complications from tunneled hemodialysis catheters: A Canadian observational cohort study. Am J Kidney Dis 2019; 73(4): 467-475. https://doi.org/10.1053/j.ajkd.2018.10.014

10. Zou Y, Ma Y, Chao W, Zhou H, Zong Y, Yang M. Assessment of complications and short-term outcomes of percutaneous peritoneal dialysis catheter insertion by conventional or modified Seldinger technique. Ren Fail 2021; 43(1): 919-925.

https://doi.org/10.1080/0886022X.2021.1925296

11. Kalantar-Zadeh K, Jafar TH, Nitsch D, Neuen BL, Perkovic V. Chronic kidney disease. Lancet 2021; 398(10302): 786-802.

https://doi.org/10.1016/S0140-6736(21)00519-5

12. Ebert T, Neytchev O, Witasp A, Kublickiene K, Stenvinkel P, Shiels PG et al. Inflammation and oxidative stress in chronic kidney disease and dialysis patients. Antioxid Redox Signal 2021; 35(17): 1426-1448. https://doi.org/10.1089/ars.2020.8184

13. Faponle AE, Olatise OO, Igbokwe M, Asaolu SO. Outcomes of tunneled and nontunneled internal jugular catheters for hemodialysis at Zenith Medical and Kidney centre, Nigeria. Niger J Med 2020; 29(3): 455-459.

https://doi.org/10.4103/NJM.NJM_77_20

14. Asif A. Reducing Tunneled Hemodialysis Catheter Morbidity: Reducing the Morbidity of Tunneled Hemodialysis Catheters-A Symposium. Semin Dial 2008; 21(6): 503.

https://doi.org/10.1111/j.1525-139X.2008.00493.x

15. Mohazzab A, Khavanin ZM, Dehesh P, Abdolvand N, Rahimi Z, Rahmani S. Investigation of risk factors for tunneled hemodialysis catheters dysfunction: competing risk analysis of a tertiary center data. BMC Nephrol 2022; 23(1).

https://doi.org/10.1186/s12882-022-02927-z

16. Coker MA, Black JR, Li Y, Varma R, Almehmi A, Abdel AAK, et al. An analysis of potential predictors of tunneled hemodialysis catheter infection or dysfunction. J Vasc Access 2019; 20(4): 380-385. https://doi.org/10.1177/1129729818809669

17. Lee O, Raque JD, Lee LJ, Wivell W, Block CA, Bettmann MA. Retrospective assessment of risk factors to predict tunneled hemodialysis catheter outcome. J Vasc Interv Radiol 2004; 15(5): 457-461. https://doi.org/10.1097/01.RVI.0000124942.24134.62

18. Martin K, Lorenzo YSP, Leung PYM, Chung S, O’flaherty E, Barker N, et al. Clinical Outcomes and Risk Factors for Tunneled Hemodialysis Catheter-Related Bloodstream Infections. Open Forum Infect Dis 2020; 7(6): ofaa117.https://doi.org/10.1093/ofid/ofaa117

19. Lok CE, Huber TS, Lee T, Shenoy S, Yevzlin AS, Abreo K, et al. KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update. Am J Kidney Dis 2020; 75(4): S1–164.

https://doi.org/10.1053/j.ajkd.2019.12.001

Downloads

Published

26-11-2026

Issue

Section

Original Articles

How to Cite

1.
Akbar RJ, Sabir S, Raja KM, Shah SA, Malik UI, Wajiha. An Analysis of Potential Predictors of Tunneled Haemodialysis Catheter Infection or Dysfunction. Pak Armed Forces Med J [Internet]. 2026 Nov. 26 [cited 2026 Nov. 29];76(7):909-12. Available from: https://www.pafmj.org/PAFMJ/article/view/11511