Estimation of Accuracy of Umbilical Venous Catheter Insertion Depth using Body Weight or Body Measurement at a Tertiary Care Hospital in Peshawar
DOI:
https://doi.org/10.51253/pafmj.v76i2.12189Keywords:
Central Venous Catheterization, In-Dwelling Catheter, Neonate, Umbilical Cord, Umbilical Veins.Abstract
Objective: To determine the accuracy of Umbilical Venous Catheter (UVC) depth of insertion using the body weight or body measurement method.
Study Design: Quasi-experimental study.
Place and Duration of Study: Neonatal Intensive Care Unit of Combined Military Hospital, Peshawar Pakistan, from Jan to Jun 2023.
Methodology: A total of 60 neonates who were passed UVC were included in the study. UVC depth insertion estimation was done by either Shukla method or by Dunn Normogram. Group-A had UVC depth of insertion estimated by body weight, while the Group-B had estimation using body measurement. Various demographic and clinical factors were recorded. The accuracy of UVC placement was then determined on an antero-posterior chest radiograph.
Results: Mean gestational age of 60 babies was 35.10±1.88 weeks and mean weight was 2.10±0.43kg. Of these 24(56.7%) were male babies, 41(68.3%) were born prematurely, 35(58.3%) had UVC placed on first or second day of life. Overall, success of a well-aligned UVC was 66.7% i.e. 40 neonates. UVC was well aligned in 16(53.3%) of the neonates measured by Shukla method, and 24(80%) plotted by Dunn Normogram. There was a statistically significant difference between methods (p=0.02).
Conclusion: The study concluded that a majority of Umbilical Venous Catheter (UVCs) are well aligned irrespective of the method used. When compared, the assessment by body measurement method fares significantly better than body weight method.
Downloads
References
1. Muzzamil M, Nisa M, Raza S. The survival rate of neonates in Pakistan: Problems in health care access, quality and recommendations. Health Promot Perspect 2022; 12(4): 355–357.
http://dx.doi.org/10.34172/hpp.2022.46
2. Liu L, Oza S, Hogan D, Perin J, Rudan I, Lawn JE, et al. Global, regional, and national causes of child mortality in 2000-13, with projections to inform post-2015 priorities: an updated systematic analysis. Lancet 2015; 385(9966): 430–440.
http://dx.doi.org/10.1016/S0140-6736(14)61698-6
3. World Health Organization. Every newborn: an action plan to end preventable deaths 2014. (Internet). Accessed on March 25th 2024. Available from:
https://www.who.int/initiatives/every-newborn-action-plan
4. Lewis K, Spirnak PW. Umbilical Vein Catheterization. 2023 Mar 19. In: StatPearls Treasure Island (FL): StatPearls Publishing 2023. (Internet). Accessed on March 25th 2024. Available from:
https://www.ncbi.nlm.nih.gov/books/NBK549869/
5. Nisar YB, Dibley MJ. Determinants of neonatal mortality in Pakistan: secondary analysis of Pakistan Demographic and Health Survey 2006-07. BMC Public Health 2014; 14(1): 663.
http://dx.doi.org/10.1186/1471-2458-14-663
6. Dunn PM. Localization of the umbilical catheter by post-mortem measurement. Arch Dis Child 1966; 41(215): 69–75.
http://dx.doi.org/10.1136/adc.41.215.69
7. Shukla H, Ferrara A. Rapid estimation of insertional length of umbilical catheters in newborns. Am J Dis Child 1986; 140(8): 786–788.
8. Kaur A, Manerkar S, Patra S, Kalamdani P, Kalathingal T, Mondkar J. Ultrasound-guided umbilical venous catheter insertion to reduce rate of catheter tip malposition in neonates: A randomized, controlled trial. Indian J Pediatr 2022; 89(11): 1093–1098. http://dx.doi.org/10.1007/s12098-022-04295-w
9. Bhutta Z. Priorities in newborn care and development of clinical neonatology in Pakistan. J Coll Physicians Surg Pak 1997; 7(6): 231–234.
10. Reynolds RD, Pilcher J, Ring A, Johnson R, McKinley P. The Golden Hour: care of the LBW infant during the first hour of life one unit’s experience. Neonatal Netw 2009; 28(4): 211–219.
http://dx.doi.org/10.1891/0730-0832.28.4.211
11. Kieran EA, Laffan EE, O’Donnell CPF. Estimating umbilical catheter insertion depth in newborns using weight or body measurement: a randomised trial. Arch Dis Child Fetal Neonatal Ed 2016; 101(1): F10-15.
http://dx.doi.org/10.1136/archdischild-2014-307668
12. Gomella T, Eyal F, Bany-Mohammed F. Gomella’s neonatology, eighth edition. 8th ed. Columbus, OH: McGraw-Hill Education; 2020.
13. Haque K, Waqar T. Collaborative Network of Neonatal Services to Reduce Neonatal Mortality and Improve Outcome: Army Medical Corps Could Lead the Way. Pak Armed Forces Med J 2020; 70(4): 1214-1219.
14. Goh SSM, Kan SY, Bharadwaj S, Poon WB. A review of umbilical venous catheter-related complications at a tertiary neonatal unit in Singapore. Singapore Med J 2021; 62(1): 29–33.
http://dx.doi.org/10.11622/smedj.2019140
15. Sletner L, Rasmussen S, Jenum AK, Nakstad B, Jensen OHR, Vangen S. Ethnic differences in fetal size and growth in a multi-ethnic population. Early Hum Dev 2015; 91(9): 547–554.
http://dx.doi.org/10.1016/j.earlhumdev.2015.07.002
16. Tambasco CJ, Shabanova V, Peterec SM, Bizzarro MJ. A novel and accurate method for estimating umbilical arterial and venous catheter insertion length. J Perinatol 2021; 41(7): 1633–1637. http://dx.doi.org/10.1038/s41372-021-01121-7
17. Cao J, Zhang Y, Yin Y, Liu Y. Accuracy of chest radiography compared to ultrasound for positioning the umbilical venous catheter in neonates: A meta-analysis and systematic review. J Vasc Access 2021; 11297298211046756.
http://dx.doi.org/10.1177/11297298211046755
18. Lean WL, Dawson JA, Davis PG, Theda C, Thio M. Accuracy of five formulae to determine the insertion length of umbilical venous catheters. Arch Dis Child Fetal Neonatal Ed 2019; 104(2): F165–169. http://dx.doi.org/10.1136/archdischild-2017-314280
19. D’Andrea V, Prontera G, Rubortone SA, Pezza L, Pinna G, Barone G, et al. Umbilical venous catheter update: A narrative review including ultrasound and training. Front Pediatr 2021; 9: 774705. http://dx.doi.org/10.3389/fped.2021.774705
20. Verheij GH, TePas AB, Witlox RSGM, Smits-Wintjens VEHJ, Walther FJ, Lopriore E. Poor accuracy of methods currently used to determine umbilical catheter insertion length. Int J Pediatr 2010; 873167.
http://dx.doi.org/10.1155/2010/873167
21. Surak A, Miller M, Roukema H. Predictors of umbilical venous catheter misalignment. Pediatr Rep 2022; 14(4): 396–400.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Shumaila Murtaza, Asma Razzaq, Syed Awais ul Hassan Shah, Asbah Rahman, Sadaf Ibrahim, Shakeel Ahmad

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.





