Diagnostic Accuracy of 16 Slice Contrast Enhanced CT Scan for Detection of Malignancy in Patients with Complex Adnexal Masses on Ultrasonography (Taking Histopathology as Gold Standard)

Authors

  • Sana Sharif Department of Radiology, Naval Ship Shifa Hospital Karachi Pakistan
  • Asma Afzal Kiani Department of Radiology, Naval Ship Shifa Hospital Karachi Pakistan
  • Nazia Mushtaq Department of Radiology, Naval Ship Shifa Hospital, Karachi Pakistan
  • Fareeha Khalid Department of Obs & Gynae, Naval Ship Hafeez Hospital, Islamabad Pakistan
  • Muhammad Uzair Department of Radiology, Naval Ship Shifa Hospital Karachi Pakistan
  • Unaiza Sharif Department of Medicine, Holy Family Hospital, Rawalpindi Pakistan

DOI:

https://doi.org/10.51253/pafmj.v73i3.8699

Keywords:

16-slice contrast-enhanced computed tomography, Diagnostic accuracy, Unexplained adnexal mass

Abstract

Objective: To determine the diagnostic accuracy of a 16-slice contrast-enhanced CT scan (CECT) for the detection of malignancy in patients with complex adnexal masses on Ultrasonography (USG) (taking histopathology as the gold standard).

Study Design: Cross-sectional study.

Place and Duration of Study: Pakistan Naval Ship Shifa Hospital, Karachi Pakistan, from Jul to Dec 2020.

Methodology: Seventy-five patients with adnexal masses were included. All patients had 16-slice contrast-enhanced CT scans. All the patients then had exploratory laparotomy, followed by histopathology as the gold standard. The diagnostic accuracy of CECT (contrast-enhanced computed tomography) was detected by determining sensitivity, specificity and diagnostic accuracy.

Results: 16-slice contrast-enhanced computed tomography showed a sensitivity of 92.2%, specificity of 93.4%, and diagnostic accuracy of 93.1%.for correctly diagnosing adnexal malignancy.

Conclusion: Due to its high sensitivity, specificity and diagnostic accuracy, 16 slice contrast-enhanced CT scan is a reliable test for diagnosing malignancy among patients with unexplained adnexal masses on USG.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Downloads

Published

21-06-2023

How to Cite

Sharif, S., Kiani, A. A., Mushtaq, N., Khalid, F., Uzair, M., & Sharif, U. (2023). Diagnostic Accuracy of 16 Slice Contrast Enhanced CT Scan for Detection of Malignancy in Patients with Complex Adnexal Masses on Ultrasonography (Taking Histopathology as Gold Standard). Pakistan Armed Forces Medical Journal, 73(3), 806–09. https://doi.org/10.51253/pafmj.v73i3.8699