Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Detection of Raised Intracranial Pressure in Critically Ill Patients; A Novell, Non-Invasive and Point of Care Test

Authors

  • Rahmat Ullah Khan Department of Anesthesia & Critical Care Medicine, Pakistan Institute of Medical Sciences, Shaheed Zulfiqar Ali Bhutto Medical University, Islamabad
  • Rana Imran Sikandar Department of Anesthesia & Critical Care Medicine, Pakistan Institute of Medical Sciences, Shaheed Zulfiqar Ali Bhutto Medical University, Islamabad
  • Najma Khurshid Department of Anesthesia & Critical Care Medicine, Pakistan Institute of Medical Sciences, Shaheed Zulfiqar Ali Bhutto Medical University, Islamabad
  • Salman Shafi Department of Anesthesia & Critical Care Medicine, Pakistan Institute of Medical Sciences, Shaheed Zulfiqar Ali Bhutto Medical University, Islamabad
  • Abdul Bari Department of Anesthesia & Critical Care Medicine, Pakistan Institute of Medical Sciences, Shaheed Zulfiqar Ali Bhutto Medical University, Islamabad
  • Muhammad Iqbal Memon Department of Anesthesia & Critical Care Medicine, Pakistan Institute of Medical Sciences, Shaheed Zulfiqar Ali Bhutto Medical University, Islamabad

DOI:

https://doi.org/10.51253/pafmj.v75iSUPPL-5.13704

Keywords:

Intra Cranial Pressure, Optic Nerve sheath diameter, Traumatic Brain Injury

Abstract

Objective: To determine the diagnostic accuracy of bedside Ultrasonographic measurement of Optic Nerve Sheath Diameter for detection of raised Intracranial Pressure in critically ill patients in comparison with CT scan brain.

Study Design: Prospective longitudinal study

Place and Duration of Study: Department of Anesthesia and Critical Care Medicine, Pakistan Institute of Medical Sciences, Shaheed Zulfiqar Ali Bhutto Medical University Islamabad, Pakistan from Jun to Nov 2019.

Methodology: Patients with clinical suspicion of raised ICP underwent Ultrasonographic measurement of ONSD by Principal Investigator within one hour prior to shifting of the patients to Radiology suite for CT scan brain to prevent diagnosis bias. The Ultrasonographic measured ONSD value of 5.0 mm was the cutoff limit for detecting raised ICP in our study. The CT scan brain reports were considered positive if findings suggested radiological features of raised ICP like Cerebral edema/effacement of ventricle or cisterns, midline shift or sub arachnoid haemorrhage. The diagnostic accuracy of Ultrasonographic measurement of ONSD for detection of raised ICP was then determined by comparing the results with radiological diagnosis of raised ICP by CT scan brain.

Results: We enrolled total 120 patients in this study. The patients included in our study were suffering from different diseases like Traumatic Brain Injury (TBI), Meningitis, Encephalitis, Space Occupying Lesions (SOLs), Eclampsia, Stroke and Metabolic encephalopathy with different percentages. The ultrasonographic measured ONSD value range was from minimum 4.7 to maximum 6.9 with mean value of 6.1 mm. The sensitivity was 95.5%, specificity 91.3%, positive predictive value 93.2%, negative predictive value 98.5% where ultrasonographic measured ONSD value of 5.0 mm was taken as a cutoff limit. In our study ultrasonographic measured ONSD values showed good diagnostic accuracy for raised ICP detection in comparison with CT scan brain.

Conclusion: We found that ONSD measured through bedside ultrasound is very useful for diagnosis and risk stratification of incipient intracranial hypertension in pregnant patients with pre-eclampsia and eclampsia where invasive monitoring is hazardous due to deranged coagulation profile.

Downloads

Download data is not yet available.

References

1. Dunn LT, Raised intracranial pressure. J Neurol NeurosurgPsychiatry 2002; 73: 23–27.

2. Tayal VS, Neulander M, Norton HJ, Foster T, Saunders T,Blaivas M. Emergency department sonographic measurement ofoptic nerve sheath diameter to detect findings of increasedintracranial pressure in adult head injury patients. Ann EmergMed 2007; 49(4): 508–514.

3. Shen L, Wang Z, Su Z, Effects of intracranial pressuremonitoring on mortality in patients with severe traumatic braininjury: a meta-analysis. PLoS One 2016, 11: e0168901.https://doi.org/10.1371/journal.pone.0168901

4. Bekar A, Doğan S, Abas F.: Risk factors and complications ofintracranial pressure monitoring with a fiberoptic device. J ClinNeurosci 2009, 16: 236-240.

5. Raboel PH, Bartek J Jr., Andresen M, Bellander BM, Romner B.Intracranial pressure monitoring: Invasive versus non-invasivemethods – A review. Crit Care Res Pract 2012; 2012: 950393.

6. Kalantari H, Jaiswal R, Bruck I, Matari H, Ghobadi F, Weedon Jet al: Correlation of optic nerve sheath diameter measurementsby computed tomography and magnetic resonance imaging. AmJ Emerg Med 2013; 31: 1595-1597.

7. Ohle R, McIsaac SM, Woo MY, Perry JJ: Sonography of the opticnerve sheath diameter for detection of raised intracranialpressure compared to computed tomography: a systematicreview and meta‐analysis. J Ultrasound Med 2015; 34: 1285-1294.

8. Hassen GW, Bruck I, Donahue J, et al.: Accuracy of optic nervesheath diameter measurement by emergency physicians usingbedside ultrasound. J Emerg Med 2015; 48: 450-457.

9. Shevlin C. Optic Nerve Sheath Ultrasound for the BedsideDiagnosis of Intracranial

10. Hypertension: Pitfalls and Potential. Critical Care Horizons2015; 1: 22-30.

11. Rajajee V, Vanaman M, Fletcher JJ, Jacobs TL. Optic nerveultrasound for the detection of raised intracranial pressure.Neurocrit Care 2011; 15(3): 506.

12. Hansen HC, Helmke K. Validation of the optic nerve sheathresponse to changing cerebrospinal fluid pressure: ultrasoundfindings during intrathecal infusion tests. J Neurosurg. 1997Jul;87(1):34–40.

13. Beckmann U, Gillies DM, Berenholtz SM, Wu AW, Pronovost P.Incidents relating to the intra-hospital transfer of critically illpatients. An analysis of the reports submitted to the AustralianIncident Monitoring Study in Intensive Care. Intensive CareMed. 2004;30:1579-85.

14. Major R, Girling S, Boyle A: Ultrasound measurement of opticnerve sheath diameter in patients with a clinical suspicion ofraised intracranial pressure. Emerg Med J. 2011, 28:67981.

15. Munawar K, Khan M, Hussain S, et al. (February 27, 2019) OpticNerve Sheath Diameter Correlation with Elevated IntracranialPressure Determined via Ultrasound. Cureus 11(2): e4145. DOI10.7759/cureus.4145

16. Jeon JP, Lee SU, Kim S-E, Kang SH, Yang JS, Choi HJ, et al.(2017) Correlation of optic nerve sheath diameter with directlymeasured intracranial pressure in Korean adults using bedsideultrasonography. PLoS ONE 12(9): e0183170.

17. Chen LM, Wang LJ, Hu Y, Jiang XH, Wang YZ, Xing YQ:Ultrasonic measurement of optic nerve sheath diameter: a noninvasivesurrogate approach for dynamic, real-time evaluationof intracranial pressure. Br J Ophthalmol 103:437– 441, 2019.

18. Bekerman I, Sigal T, Kimiagar I, Vaiman M: Initial evaluation ofthe intracranial pressure in cases of traumatic brain injurywithout hemorrhage. J NeurolSci 368:285–289, 2016.

19. Juxiang Wang, Ke Li, Hongjia Li, Chengyi Ji, Ziyao, HuiminChen and Bin Chen, Ultrasonographic optic nerve sheathdiameter correlation with ICP and accuracy as a tool fornoninvasive surrogate ICP measurement in patients withdecompressive craniotomy. J Neurosurg 133:514–520, 2020.

20. Jeon JP, Lee SU, Kim S-E, Kang SH, Yang JS, Choi HJ, et al.(2017) Correlation of optic nerve sheath diameter with directlymeasured intracranial pressure in Korean adults using bedsideultrasonography. PLoS ONE 12(9): e0183170.

21. Bokslag A, van Weissenbruch M, Mol BW, et al. (2016)Preeclampsia; short and long-term consequences for mother andneonate. Early Hum Dev 102: 47–50.

22. Grotegut CA (2016) Prevention of preeclampsia. J Clin Invest126: 4396–4398.

23. Ghulmiyyah L, Sibai B (2012) Maternal mortality frompreeclampsia and eclampsia. Semin Perinatol 36: 56–59.

24. Singh SK, Bhatia K. Ultrasonographic optic nerve sheathdiameter as a surrogate measure of raised intracranial pressurein severe pregnancy-induced hypertension patients. AnesthEssays Res 2018;12:42-6.

25. Bala R, Banerjee A, Taxak S, Kumar R. Optic nerve sheathdiameter measured using ocular sonography is raised in patientswith eclampsia. J Obstet Anaesth Crit Care 2019;9:65-9.

Downloads

Published

31-07-2025

Issue

Section

Original Articles

How to Cite

1.
Khan RU, Sikandar RI, Khurshid N, Shafi S, Bari A, Memon MI. Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Detection of Raised Intracranial Pressure in Critically Ill Patients; A Novell, Non-Invasive and Point of Care Test. Pak Armed Forces Med J [Internet]. 2025 Jul. 31 [cited 2025 Aug. 1];75(SUPPL-5):S817-S821. Available from: https://www.pafmj.org/PAFMJ/article/view/13704